The minimum live loads per square meter area for different types of structures are given in is 875 part 2 1987.
Roof live load for residential building.
50 psf x 14ft 700 pounds per lineal foot.
15 psf x 14ft 210 pounds per lineal foot.
1 inch 25 4 mm 1 square inch 645 16 mm 2 1 pound per square foot 0 0479 kn m 2 1 pound 0 004448 kn 1 pound per cubic foot 16 kg m 3.
It is important to list live load dead load and total load separately because live load is used to compute stiffness and total load is used to calculate strength.
3 20 residential structural design guide.
It is one of the major loads in structural design.
Load types loads used in design load equations are given letters by type.
Is 875 part ii 1987 specifies the live loads for following occupancy conditions.
In areas where the ground snow load is less than 15 psf the minimum roof live load refer to section 3 4 is usually the controlling rgavity load in roof design.
Floors in garages or portions of buildings used for the storage of motor vehicles shall be designed for the uniformly distributed live loads of table 1607 1 or the following concentrated loads.
On a roof with a slope greater than 4 to 12 the live load limit is typically adjusted downward from 20 psf to 15 psf to allow for the relatively greater dead load on the steeper roof.
In other words on a steep roof less material would be stacked in a concentrated area at one time to avoid having it slide off.
1607 13 4 awnings and canopies.
D dead load l live load l r live roof load w wind load s snow load e earthquake load r rainwater load or ice water load.
In my region on cape cod we have a ground snow load design of 25 psf which is a greater design load than the live load 12 psf to 20 psf over an entire roof system.
The uniform design live load in unoccupied landscaped areas on roofs shall be 20 psf 0 958 kn m 2.
Used but they typically defined the load cases or combination stress or strength limits and deflection limits.
Building codes such as the ibc reference asce 7 minimum design loads for buildings and other structures for the determination of design snow loads on buildings.
The uniform design live load for occupied landscaped areas on roofs shall be determined in accordance with table 1607 1.
1 for garages.
Chapter 3 design loads for residential buildings.
For a larger map with greater detail refer to asce 7 98.
The roof snow load is defined as the weight of.
Notes to table 1607 1 for si.
Live loads should be suitably calculated or assumed by the designer based on occupancy levels.
To correctly apply the values of the tables and the prescriptive methods of construction build ers must know the structural design criteria in the planning chapter of the code.